Specification |
Type |
SF1-G3 |
SF2-G3 |
SF3-G3 |
SF1-G0 |
SF1-G0 |
SF3-G0 |
Number of poles Typical Heinemann Units |
|
|
|
|
|
|
Standard Current Ratings(A) |
1-5-10 15-20-25 30-35-40 45-50-60 70-80-90 100 |
1-5-10 15-20-25 30-35-40 45-50-60 70-80-90 100 |
1-5-10 15-20-25 30-35-40 45-50-60 70-80-90 100 |
60 & 100 |
60 & 100 |
60 & 100 |
Rated Breaking Capacity 240/415V AC |
6kA |
6kA |
6kA |
- |
- |
- |
Withstand Current |
- |
- |
- |
6kA |
6kA |
6kA |
Rated Voltage AC |
240V |
240V |
415V |
240V |
240V |
415V |
Max Current Rating |
100A |
100A |
100A |
100A |
100A |
100A |
Time Delay Curve |
1 or 2 |
2 |
1 or 2 |
- |
- |
- |
Sensitivity |
- |
- |
- |
- |
- |
- |
Number of modules |
1 |
2 |
3 |
1 |
2 |
3 |
Dimensions(mm) |
H |
107 |
107 |
107 |
107 |
107 |
107 |
W |
26 |
52 |
78 |
26 |
52 |
78 |
D |
66 |
66 |
66 |
66 |
66 |
66 |
Colour of handle |
white |
white |
white |
green |
green |
green |
Standard approval |
IEC 157-1973 BS 4752-1977 BS 3871 Partl 1965 Amended 1983 AS 3111 AS 2184 SAZ 299-1991 |
IEC 157-1973 BS 4752-1977 BS 3871 Partl 1965 Amended 1983 AS 3111 AS 2184 SAZ 299-1991 |
IEC 157-1973 BS 4752-1977 BS 3871 Partl 1965 Amended 1983 AS 3111 AS 2184 SAZ 299-1991 |
IEC 408-1972 BS 5419-1977 SAZ 299-1991 |
IEC 408-1972 BS 5419-1977 SAZ 299-1991 |
IEC 408-1972 BS 5419-1977 SAZ 299-1991 |
Load Limiters Trip Between |
101-115% |
101-115% |
101-115% |
|
|
|
Colour of handle |
red |
red |
red |
|
|
| |
|
Product Description |
Product Reference |
Product Type |
Description |
1 2 3 4 5 6 |
SF1-G3 SF2-G3 SF2-G3 SF1-G0 SF2-G0 SF2-G0 |
Single pole MCB up to 100 Amps AC. Double pole MCB up to 100 Amps AC. Triple pole MCB up to 100 Amps AC. Single pole disconnector up to 100 Amps AC. Double pole disconnector up to 100 Amps AC. Triple pole disconnector up to 100 Amps AC. | |
Note: The SF range of 6kA circuit breakers are suitable for industrial and commercial installation protection i.e. for factories, apartment buildings,high rise commercial buildings and in mini-substations and kiosks, where a 6kA breaking capacity is required. All the SF range of products clip directly onto the Heinemann Mini-rail.Should the distribution board be fitted with a clip tray, use the adaptor plate. The 6kA SF range of circuit breakers can be used fr motor protection. Queries can be made to your nearest Heinemann dealer. Details available on the back. |
|
Frame size |
Type |
Standard Current Ratings(A) |
Fault level kA |
Dimensions in mm |
NO.OF poles |
Mountings
|
Features |
240V |
415V |
Height |
Width |
Depth |
Rail |
Surface |
|
SA1 |
1-50 |
3 |
- |
82 |
13 |
66 |
1 |
¡Ì |
With mounting clips |
Hydraulic magnetic. Low instantaneous trip point 4x1n. Standard Curve 2, time delay. |
SA2 |
1-50 |
3 |
- |
82 |
26 |
66 |
2 |
SA3 |
1-50 |
3 |
3 |
82 |
39 |
66 |
3 |
SA2-G0/G3 |
5-60 |
3 |
- |
82 |
26 |
66 |
1+N |
SA-G0 Isolator |
60 |
3 |
3 |
82 |
As for MCBs |
66 |
1,2,3,4 |
|
SF1 |
1-100 |
6 |
- |
107 |
26 |
66 |
1 |
¡Ì |
With mounting clips |
Hydraulic magnetic. Low instantaneous trip point 10 to 12xIn. Time delay curves Standard curve 2. Long time delay Curve 1. Load limiters. AC & DC application. |
SF2 |
1-100 |
6 |
- |
107 |
52 |
66 |
2 |
SF3 |
1-100 |
6 |
6 |
107 |
78 |
66 |
3 |
SF2-G0/G3 |
5-100 |
6 |
- |
107 |
52 |
66 |
1+N |
SF-G0 Isolator |
60,100 |
6 |
6 |
107 |
As for MCBs |
66 |
1,2,3,4 |
|
SX1 |
10-120 |
6 |
- |
132 |
26 |
57 |
1 |
- |
Direct surface mounting via fixing screws |
Hydraulic magnetic. Low instantaneous trip point 10 to 12xIn. Time delay curves Standard curve 2. Long time delay Curve 1. Load limiters. Direct mounting with screws. Clip-on shrouds. |
SX2 |
10-100 |
6 |
- |
132 |
52 |
57 |
2 |
SX3 |
10-100 |
6 |
6 |
132 |
78 |
57 |
3 |
SX2-G0/G3 |
10-100 |
6 |
- |
132 |
52 |
57 |
1+N |
SX4-G0/G3 |
10-100 |
6 |
- |
132 |
88 |
57 |
3+N |
|
SH1 |
10-100 |
10 |
- |
107 |
26 |
66 |
1 |
¡Ì |
With mounting clips |
Hydraulic magnetic. High instantaneous trip point 10 to 12xIn. Time delay curves Standard curve 2. Long time delay Curve 1. Load limiters. |
SH2 |
10-100 |
10 |
- |
107 |
52 |
66 |
2 |
SH3 |
10-100 |
10 |
10 |
107 |
78 |
66 |
3 |
SH2-G0/G3 |
10-100 |
10 |
- |
107 |
52 |
66 |
1+N |
SH-G0 Isolator |
60,100 |
10 |
10 |
107 |
As for MCBs |
66 |
1,2,3,4 |
|
QA1 |
1-50 |
3 |
- |
82 |
13 |
66 |
1 |
¡Ì
|
With mounting clips
|
Hydraulic magnetic. Low instantaneous trip point 4x1n. Standard Curve 2, time delay.
|
QA2 |
1-50 |
3 |
- |
82 |
26 |
66 |
2 |
QA3 |
1-50 |
3 |
3 |
82 |
39 |
66 |
3 |
QA2-G0/G3 |
5-60 |
3 |
- |
82 |
26 |
66 |
1+N |
QA-G0 Isolator |
60 |
3 |
3 |
82 |
As for MCBs |
66 |
1,2,3,4 | |
|
Frame size |
Type |
Technical data |
Application |
Features |
|
LIGHTING ARRESTOR-SAL,LAS: |
Rated voltage:240V at 50/60Hz Rated nominal discharge:5000A(peak) 8/20 micro seconds Minimum spark over voltage:800V rms Maximum spark over voltage:1000V rms Maximum impulse spark over voltage:2500V(peak) Gapped type with non-linear silicon carbide resistor. |
For protection of residential, commercial and industriall wiring installations against voltage surges caused by lightning or other phenomena. |
¡ñCompact size ¡ñIndoor Type SAL clips into mini-rail or surface mounted with MK1 clips ¡ñOutdoor Type LAS resistant to environmental conditions, complete with mounting brackets and line cable. |
|
LIGHTING ARRESTOR-QFL-1(13) |
Rated voltage:240V at 50/60Hz Rated nominal discharge:5000A(peak) 8/20 micro seconds Minimum spark over voltage:800V rms Maximum spark over voltage:1000V rms Maximum impulse spark over voltage:2500V(peak) |
For protection of residential, commercial and industriall wiring installations against voltage surges caused by lightning or other phenomena. |
¡ñCompact size ¡ñIndoor Type SAL clips into mini-rail or surface mounted with MK1 clips |
|
BUSBARS SINGLE AND THREE PHASE: |
Current carrying capacity:single phase 60A perbusbar three phase 100A Short circuit stability:Type SA-3kA SF/SH-10kA Insulation voltage for three phase:3Kv |
For single/three phase loop connection of MCB¡¯s |
¡ñQuick and easy installation ¡ñAvailable lengths: SA single phase 702mm,(54 MCB¡¯s) SF/SH single phase 936mm,(36 MCB¡¯s) SA three phase 1M,(25 MCB¡¯s) SF/SH three phase 1M,(12 MCB¡¯s) |
|
DIN RAIL |
Enclosure TC3/TC4:3 or 4 way |
Used for surface mounting of SA,Lighting arrestor. |
¡ñQuick and easy installation ¡ñAvailable lengths: SA single phase 1000mm(108 MCB¡¯s) SA three phase 1000mm(36 MCB¡¯s) Lightning arrestor 1000mm(108 PCS) |
|
ENCLOSURES |
Enclosure TC3/TC4:3 or 4 way |
Used for surface mounting of SA, SH circuit breaker or auxiliary products to cover access to terminals. |
¡ñMoulded in self-extinguishing ¡ñThermoplastic TC3/TC4 provided with moulded mini-rail. ¡ñSealing facilities for "plumb wire". ¡ñGives complete shielding of the line and load terminals. ¡ñMCB¡¯s are easily seen throuth the cut-outs. ¡ñMCB¡¯s are mounted with clips and woodscrews. | | |